The electrical connections must comply with current
legislation and be made by a suitably qualified
professional.
Information on the voltage and power consumed is provided on
the rating plate.
The appliance must be earthed.
When installing the appliance, we recommend fitting an all-
pole disconnection device with contacts that open 3 mm.
If damaged, the power supply cable must be replaced with
an identical one (H05V2V2-FT90 ºC or H05RR-F). We
recommend that you have this work carried out by our After-
sales Service. Please contact our Customer Care Centre on
00800-3810-4026.
Do not use extension cables.
The manufacturer cannot be held liable for injuries to
persons or pets or for damage to goods caused by failure to
comply with the regulations above.
L
Earth
(yellow/green)
N
1. After cleaning the surface around the edges, fit the seal provi-
ded.
2. Position the hob in the opening, maintaining the clearances bet-
ween the hood and/or cabinets indicated on page 6.
3. Use the brackets (A) provided to secure the hob to the worktop
with screws.
Note: The power supply cable must be long enough to allow the
hob to be removed from above.