If a hood will be installed over the hob, refer to the hood installation instructions to ensure that the cor-
rect clearance above the hob is maintained.
Note: If the distance "A" between the wall cupboards is between 600 mm and 730 mm, the height "B"
must be at least 530 mm.
If the distance "A" between the wall cupboards is greater than the width of the hob, the height "B" must
be at least 400 mm.
6
Category
II2H3+
Electricity supply: 220-240 V ~ 50/60 Hz 0.6 W
Type of gas
Type of
burner
Injector
designation
Nominal heat
flow (kW)
Rated
consumption
Reduced heat
capacity (kW)
Gas pressure (mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
Two-ring
(outer + inner)
Inner
130H3 +70H1
70H1
3.70
0.90
352 l/h
86 l/h
2.20
0.30
17 20 25
Semi-rapid 97A 1.75 167 l/h 0.35
Auxiliary 78C 1.00 95 l/h 0.30
LIQUEFIED GAS
(Butane) G30
Two-ring
(outer + inner)
Inner
80 + 41
41
3.30
0.90
240 g/h
65 g/h
2.20
0.30
20 28-30 35
Semi-rapid 68A 1.75 127 g/h 0.35
Auxiliary 50A 1.00 73 g/h 0.30
LIQUEFIED GAS
(Propane) G31
Two-ring
(outer + inner)
Inner
80 + 41
41
3.30
0.90
236 g/h
64 g/h
2.20
0.30
25 37 45
Semi-rapid 68A 1.75 125 g/h 0.35
Auxiliary 50A 1.00 71 g/h 0.30
Type of gas
Model configuration
4 burners 2C 3.7 kW
Rated thermal flow rate (kW) Total rated consumption
Air required (m
3
) for burning
1 m
3
of gas
G20 20 mbar 2C-2SR -1AUX 8.20 781 l/h 9.52
G30 28-30 mbar 2C-2SR -1AUX 7.80 567 g/h 30.94
G31 37 mbar 2C-2SR -1AUX 7.80 557 g/h 23.80
Injectors table