To replace the injectors in the special burner:
1. Remove the burner ring (C), the screws (B) hol-
ding the cover cap in place (A) and the cap itself.
2. Unscrew the inner injector (D) and the outer
injector (E) using a 7 mm hex key.
3. Replace the injectors.
4. Refit the cover cap, screws and burner ring.
Note: Make sure that:
1. The burner ring (C) is seated correctly on the
burner following replacement.
The minimum flow level is regulated using the tap at the lowest posi-
tion (small flame) .
There is no need to regulate the primary air in the burners.
To ensure the minimum level is properly regulated, remove the con-
trol knob and adjust the screws on the tap as follows:
1. Tighten to decrease the height of the flame 1 (-)
2. Loosen to increase the height of the flame (+);
3. With the burners on, turn the control knobs from the maximum
to the minimum position to check the stability of the flame.
.
A
C
B
E
D
Regulating the minimum flow level of the gas taps
Replacing the injectors in the wok burner