6
If a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct
height above the hob
Hood and cabinetry clearances (mm)
Category
II2L3B/P
Electric supply: 220-240 V ~ 50/60 Hz 0,6W
Injectors table
Type of gas used
Ty p e o f
burner
Injector marketing
Nominal heat flow
kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure mbar
min.
nom.
max.
ERDGA
(Butangas) G25
2 ring
(outer + inner)
Inner
124F3 + 68F1
68F1
3,70
0,90
409 l/h
100 l/h
2,20
0,30
20
25
30
semi-rapid
102D
1,75
194 l/h
0,35
auxiliary
79B
1,00
111 l/h
0,35
LIQUEFIED GAS
(Butane) G30
(Propane) G31
2 ring
(outer + inner)
Inner
80 + 41
41
3,30
0,90
316240 g/h
65 g/h
2,20
0,30
25
30
35
semi-rapid
68A
1,75
127 g/h
0,35
auxiliary
50A
1,00
73 g/h
0,30
Type of gas used
Model configuration
4 burners 2C 3,7kW
Rated thermal flow rate kW Total rated consumption
Air required (m
3
) for burning
1 m
3
of gas
G25 25 mbar 2C-2SR -1AUX 8,20 908 l/h 8,187
G30/G31 30 mbar 2C-2SR -1AUX 7,80 567 g/h 30,94
Comentarios a estos manuales