. R
7
Category
II2E+3+
Type of gas used Type of Injector Control primary Nominal heat Nominal Reduced heat Gas presssure
burner label air (X) (mm) flow kW consumption flow kW (mbar)
min. nom. max
BE FR
NATURAL GAS wok 178 6 6,00 571 l/h 1,50 1,50 17 20 25
(Methane) fast 125 - 3,00 286 l/h 0,80 0,60
G20 semi-fast 95 - 1,65 157 l/h 0,45 0,35
auxiliary 78 - 1,00 95 l/h 0,35 0,30
LIQUID wok 112 8 5,50 400 g/h 1,50 1,50 20 28-30 35
PETROLEUM GAS fast 90 A - 3,00 218 g/h 0,60 0,60
(Butane) G30 semi-fast 67 - 1,65 120 g/h 0,35 0,35
auxiliary 50 - 1,00 73 g/h 0,30 0,30
LIQUID wok 112 8 5,50 393 g/h 1,50 1,50 25 37 45
PETROLEUM GAS fast 90 A - 3,00 214 g/h 0,60 0,60
(Propane) G31 semi-fast 67 - 1,65 118 g/h 0,35 0,35
auxiliary 50 - 1,00 71 g/h 0,30 0,30
Type of gas used Configuration Nominal heat Overall nominal Requaired air (m
3
)
model flow kW consumption for the combustion 1 m
3
of gas
G20 20 mbar 5 burners 13,30 1266 l/h 9,52
G30 28-30 mbar 5 burners 12,80 931 g/h 30,94
G31 37 mbar 5 burners 12,80 915 g/h 23,80
Electric Power: 230 V - 50 Hz
Injectors table