If a hood is installed above the hob, read the instructions for fitting the hood where it indicates the correct
distances to be complied with.
Note: If the distance “A” between the kitchen wall cabinets is between 600 and 730 mm, height “B" shall
be at least 530 mm.
If the distance “A” between the kitchen wall cabinets is wider than the hob’s width, height “B” shall be at
least 400 mm.
Installation distances and measurements (mm)
in. R
in.
Category II2E+3+
Type of gas used Type of Injector
Control primary
Nominal heat Nominal Reduced heat Gas pressure (mbar)
burner label air (X) mm flow kW consumption flow kW min. nom. max
BE FR
NATURAL GAS wok 145 6 4,20 400 l/h 1,50 1,50 17 20 25
(Methane) G20 semi-fast 95 - 1,65 157 l/h 0,45 0,35
auxiliary 78 - 1,00 95 l/h 0,35 0,30
LIQUID wok 95 11 3,80 276 g/h 1,50 1,50 20 28-30 35
PETROLEUM GAS semi-fast 67 - 1,65 120 g/h 0,35 0,35
(Butane) G30 auxiliary 50 - 1,00 73 g/h 0,30 0,30
LIQUID wok 95 11 3,80 272 g/h 1,50 1,50 25 37 45
PETROLEUM GAS semi-fast 67 - 1,65 118 g/h 0,35 0,35
(Propane) G31 auxiliary 50 - 1,00 71 g/h 0,30 0,30
Type of gas used Configuration Nominal heat Overall nominal Required air (m
3
)
model flow kW consumption for the combustion 1 m
3
of gas
G20 20 mbar 4 burners 8,5 809 l/h 9,52
G30 28-30 mbar 4 burners 8,1 589 g/h 30,94
G31 37 mbar 4 burners 8,1 579 g/h 23,80
Electric Power: 230 V - 50 Hz
Injectors table
7